The answers below come from questions Qunli regularly hears from water treatment, food and beverage and fine chemical customers, covering parameter selection and test methods. For anything further, call 138-0589-9465 or send an enquiry.
The main differences are raw material cleanliness, acid washing and impurity control. Food grade products control ash, heavy metals and decolourisation and are made to the relevant national food safety standards for food additives; water sanitation grades must also meet drinking water safety evaluation requirements. Industrial grades focus on capacity and strength, with looser ash and metal ion limits.
Iodine value reflects micropore development and helps judge small-molecule adsorption, often used for drinking water and gas-phase work. Methylene blue value reflects mesopore adsorption of large pigment molecules, which matters more for sugar decolourisation and colour removal. CTC (carbon tetrachloride adsorption) is mostly used to assess gas-phase performance. Give your engineer the medium, target contaminant and contact time together; judging by one indicator alone is easy to get wrong.
We currently work mainly with coconut shell, coal and wood feedstocks, in granular (crushed and columnar) and powdered forms. Food grade and water sanitation grade are our main lines, with impregnated protective carbon, columnar activated coke and lithium battery grades also available.
Particle size governs pressure drop and adsorption rate: fine particles adsorb quickly but raise pressure drop, suiting polishing duties with strict effluent targets; coarse particles keep head loss low and suit high-flow filtration. A high uniformity coefficient causes stratification and channelling, so engineering practice keeps it within a sensible range and asks the supplier for sieve data.
Holds a Food Production Licence (with the licensed product list) and a business licence, and is certified to ISO 9001 quality, ISO 14001 environmental and ISO 45001 occupational health and safety systems, plus AAA credit rating and SME integrity demonstration unit certificates. Originals can be viewed on the Qualifications page.
Standard factory tests cover iodine value, methylene blue value, strength, ash, moisture, bulk density, pH and particle size distribution, to the GB/T 7702 (coal-based granular carbon) or GB/T 12496 (wood-based activated carbon) series. Third-party reports can be commissioned from CTI, SGS or similar for agreed items; cost and turnaround are confirmed separately.
Yes. Batch test reports ship with the goods and historical reports can be retrieved within the warranty period. Test data involving your formulation or process are handled under confidentiality and never disclosed.
Standard grades start at 1 tonne; 1-5 kg samples are available for trials. Sample and freight costs are confirmed case by case and can be offset in the contract after an order is placed.
Stocked standard grades ship in 7-15 days; orders needing custom particle size, acid washing or impregnation normally take 20-30 days, subject to the production schedule in the contract.
Common packs are 25 kg woven bags with a PE liner, 25 kg kraft paper bags and 500 kg bulk bags, or customised to container type and handling. Export orders can add pallets, stretch wrap and fumigation marks.
Domestic shipments mainly go by road; exports usually via Shanghai, Ningbo or Xiamen, quoted FOB or CIF. Packing lists, invoices, MSDS, non-hazardous goods certificates and certificates of origin can be supplied, subject to destination customs requirements.
Standard terms are T/T (30% deposit, balance against copy bill of lading). Credit terms can be discussed for long-term customers and L/C is accepted for large orders. The contract governs.
Activated carbon adsorbs readily: keep it dry, shaded and away from ignition sources and strong oxidisers in storage and transit. Use opened bags promptly or reseal them, or the carbon will pick up airborne organics and lose capacity.
Whether spent carbon is hazardous waste depends on what it adsorbed. Carbon used with drinking water or sugar liquor is normally general solid waste; carbon loaded with heavy metals, organic solvents or hazardous chemicals usually requires hazardous waste identification before disposal. Follow the local ecology and environment authority; we can supply a product composition statement.
Retained samples from each batch are kept for 6 months. In a dispute both parties can retest or jointly commission a third party. Confirmed product quality issues are handled by return, replacement or top-up shipment per the contract; if the duty (contact time, inlet water) is mismatched, we advise on process adjustments.
Yes. The factory is in Yihuang Industrial Zone, Fuzhou, Jiangxi. Please call 1-2 days ahead; we will arrange a technician to show the lines and lab and prepare samples of the relevant grade.
Send us the medium, target indicators and volume; a sales engineer will respond within 2 hours with samples and a data sheet.